Integrated Motor+Controller High Speed 12000rpm Pm AC Electric Motor

Integrated Motor+Controller High Speed 12000rpm Pm AC Electric Motor

Built-in Motor+Controller Large Velocity 12000RPM PM AC CZPT Motor

Product Characteristic
1.Long lasting Magnet Motor + converter specialized matched perfectly
two.Motor Pace: 12000rpm
three.Large power & higher torque
four.Higher performance, high expense functionality
five.Little measurement
6.Lower noise reduced vibration
seven.Patented cooling construction
8.Effortless routine maintenance, set up and commissioning
nine.For both h2o / oil cooling possibilities

Requirements
Design variety: SRPMU205M8O30
Voltage: 530V DC
Rated Electrical power: 30KW
Rate Torque : 23.9N.m
Operating velocity: 12000rpm
Motor Effectiveness: 96.1%
Converter Efficiency: 97.7%
Provider Factor: S1
Isolation: H/F
Drinking water/dust Evidence: IP67
Pole Quantity: 8
N Fat: 37KG
Cooling Method: Oil
Place Signal: Resolver (optional)

Other motors you will be intrigued in

Motor kind Voltage
(V DC)
Rated energy
(kW)
Rated torque (N.m) Rated speed
(rpm)
Motor effectiveness
(%)
Conversion efficiency
(%)
Obligation type  Insulation Ingress safety Pole Variety Bodyweight
(kg)
Cooling Approach Placement Signal 
SRPMU205M8O22 530 22 17.5 12000 96 98.1 S1 H/F IP67 8 35 Oil circulation Resolver
SRPMU205M8O30 530 30 23.nine 12000 96.1 97.seven S1 H/F IP67 eight 37 Oil circulation Resolver
SRPMU205M8O37 530 37 29.five 12000 ninety six.three ninety seven.5 S1 H/F IP67 eight 39 Oil circulation Resolver
SRPMU205M8O45 530 forty five 35.8 12000 96.three 97.five S1 H/F IP67 8 forty two Oil circulation Resolver
SRPMU205M8O55 530 fifty five 43.eight 12000 96.3 97.five S1 H/F IP67 8 45 Oil circulation Resolver
SRPMU205M8O70 530 70 fifty five.seven 12000 ninety six.five 97.three S1 H/F IP67 8 51 Oil circulation Resolver

FAQ
one. Can performanent magnet synchronous motor be utilised as generator? 

No. Long lasting magnet synchronous motor is totally various from generator. It is only ac motor that outputs velocity and torque to travel electrical products, but not electricity supply. 
 
two. Why can not straight use 3 stage ac provide voltage to begin long term magnet synchronous motor? 
Becuase rotor is with huge innertia, and magetic files spins so rapidly that static rotor has no way to spin with magetic submitted. 
 
three. Any special complex ask for on this motor’s VFD driver? And Do you have this sort of driver? 
Permanent magnet synchronous motor’s driver need to be vector management VFD with specific inner software program, this sort of as Siemens 6SE70 sequence, Yakawa CR5 series, ABB ACS800 collection, Mitsubishi A740 sequence, B&R P84 and P74 collection, and so forth.. Yes, our MH300 collection VFD matches with this motor. 
 
four. Is there any protecting actions to protect long term magnet rotor from failure? 
Of course, each and every everlasting magnet rotor passes corrossion resistance, consistency, higher temperature demagnetization take a look at, linear demagnetization check, and many others. Its demagnetization index is inside two%. But if operating atmosphere is significant oxiditive corrosion, kindly suggest for greater protection stage. 
 
5. In which is this everlasting magnet synchronous motor typically utilized to? 
This everlasting magnet synchronous motor is generally used to variable frequency velocity situation.

 

Integrated Motor+Controller High Speed 12000rpm Pm AC Electric Motor

Tags: